智能電池充電器的性能測試
智能電池充電器它滿(man)足12VVRLA蓄電池在循(xun)環使用(yong)條(tiao)件下的(de)充電要求(qiu),設計(ji)指標為(wei):
(1)當(dang)Ub≤14.2V時(shi),恒流充(chong)(chong)電,充(chong)(chong)電電流為2A。
(2)當Ub>14.2V時,充電電流隨電池(chi)電壓的升高而線性減小。
(3)當Ub≥15.5時,以(yi)10mA左右的電流(liu)(liu)給(gei)蓄電池(chi)充(chong)電,用以(yi)補償(chang)蓄電池(chi)自放電的電流(liu)(liu)。
(4)充電(dian)閾值電(dian)壓溫(wen)度補償系數(shu)為-23mV/℃(12VVRLA蓄電(dian)池)
測試步驟如下:
①給JTU―100型電子負載接上電源,并將輸出調整(zheng)到13.5V。
②按結構接(jie)線。
③先打開(kai)(kai)(kai)電(dian)(dian)子負(fu)載的(de)(de)開(kai)(kai)(kai)關,再打開(kai)(kai)(kai)智(zhi)能電(dian)(dian)池充電(dian)(dian)器的(de)(de)開(kai)(kai)(kai)關,電(dian)(dian)流表顯(xian)(xian)示為2A,電(dian)(dian)壓表顯(xian)(xian)示為13.5V。
④逐漸增加電(dian)(dian)(dian)子負(fu)載的輸出(chu)電(dian)(dian)(dian)壓(ya),當(dang)電(dian)(dian)(dian)壓(ya)大于14.2V時,輸出(chu)電(dian)(dian)(dian)流(liu)逐漸減小(xiao),當(dang)電(dian)(dian)(dian)子負(fu)載的輸出(chu)電(dian)(dian)(dian)壓(ya)升至(zhi)15.5V時,電(dian)(dian)(dian)流(liu)降至(zhi)10mA左右。
⑤逐(zhu)漸減小電子負載的(de)輸(shu)出電壓(ya),電流(liu)(liu)表(biao)的(de)讀數(shu)線性(xing)增(zeng)加,當輸(shu)出電壓(ya)小于14.2V時,電流(liu)(liu)表(biao)的(de)讀數(shu)增(zeng)至(zhi)2A并維持不變。
⑥為了測出充電閾值電壓的溫度補償是否達到設計指標,將智能電池充電器的溫度(du)傳感器放(fang)到恒溫箱(xiang)中(zhong),測出該溫度(du)下的充電曲線。