N100-36(36V 1.8A)30S NiMH/NiCd Battery Charger
|
Item |
Specification |
Remark |
| 1.Input |
| Rating input voltage |
100~240Vac 50/60Hz |
|
| Input voltage range |
90~264Vac |
|
| Rating input current |
1.5Arms |
Input:100V Output:Full load |
| Max input power |
100W |
Input:100V Output:Full load |
| 2.Output |
| No load output voltage |
DC 12.5 V |
|
| Output voltage range |
DC30 ~ 48 V |
|
| Suit with battery type |
30S Ni-MH/Ni-Cd battery |
|
| Charging current |
1.8A ±10% |
|
| Charging trickle |
1/10 CC Pulse |
|
| Max Charging voltage |
DC 48V |
|
| Main charge end condition |
-DV ≥5mV /cell (TYP) |
For NiCd, Vmax is 1.8V/cell |
| or Vmax≥1.6V/cell |
| or Timer out. |
| Timer |
8hours (default) |
|
| Max output power |
86.4W |
|
| Ripple voltage |
≤480 mV |
Full load |
| Charging LED |
Red:Charging |
|
| Green:Full charge or idle |
|
| Shorted |
Yes |
|
| Reversed |
Yes |
|
| Efficiency |
≥87% |
Full load @220V |
| 3.Environment |
| Operate temperature |
-10 ~ +40℃ |
|
| Operate humidity |
< +90% |
Relative humidity |
| Storage temperature |
-40 ~ +70℃ |
|
| Storage humidity |
0 ~ +95% |
Relative humidity |
| Cooling |
Natural |
|
| Vibration resistance |
5MM/50HZ/600S |
Non-operating condition |
| Impact resistance |
1 meter drop test 3 times |
Non-operating condition |
| 4.Mechanical |
| Weight |
400g |
|
| Size |
170X70X41MM |
Casing only |
| Connector |
Refer to order |
|
| 5.Safety |
| Max. temperature rise |
< 40℃ on casing |
|
| Safety approval |
CE/cTUVus/CCC/PSE |
| MTBF |
30000H |
|
| ESD |
8.0KV |
|
| Hi-Pot Insulation |
i/p to o/p: 3000V (1 min) |
|